12 CULLIGAN
®
MARK 100 WATER SOFTENER
Settings
The mircoprocessor can be set in three distinct operation modes. Aqua-Sensor
Sensing Device, Soft-Minder
meter, or Timeclock. As shipped from the factory, the control is set for 9" Timeclock operation. A set of dip
switches, located on the back of the control, may have to be changed for proper operation of the unit. Refer to
Figure 12 and Table 3 for the proper setting of these dip switches.
AQUA-SENSOR
OPERATION
The Aqua-Sensor
Sensing Device utilizes a pair of cells to sense the passage of hardness through the water
softener. It can automatically adjust for water with variable hardness levels. As a result, it is the most efficient
means of operating a water softener. When hardness is sensed, the unit signals for a regeneration. The
"REGEN" enunciator will light at this point. The unit will perform a standard regeneration cycle at the preset
time, unless the number 6 dip switch is turned on. When the number 6 dip switch is in the 'ON' position, a
regeneration will begin immediately.
The Aqua-Sensor
models contain a feature which can automatically detect when the brine solution has been
rinsed through the Cullex
media. This feature will advance the control to the next position when it senses that
the brine has been rinsed out prior to the time set in the Brine/Rinse option.
Since the Aqua-Sensor
device automatically senses hardness in the water, the programming is limited to the
Time-of-Day, Time-of-Regeneration, Salt Dosage, Backwash Time and Brine/Rinse settings. The numeric
enunciator will only light for those programming options (numbers 1-6, 9, and 10). Refer to the programming
section for further information on programming the microprocessor.
SOFT-MINDER
OPERATION
The Soft-Minder
meter utilizes a turbine impeller to accurately monitor the customers water usage. After a
predetermined amount of water has passed through the system, the microprocessor will signal a regeneration.
The "REGEN" enunciator will light at this point. The unit will perform a standard regeneration cycle at the
preset time, unless the number 6 dip switch is turned on. When the number 6 dip switch is in the 'ON' position, a
regeneration will begin immediately.
The microprocessor automatically calculates the gallons of water which can be treated based on the salt dosage,
the water hardness, and the tank size. Refer to Tables 4B and 5B for capacity and reserve values that the
microprocessor will use based on its settings. The GALLONS TO SIGNAL setting can be manually set to
directly override the microprocessor calculations. This setting can be modified when positioned at numeric
enunciator 8. The gallon value may need to be raised or lowered to meet the needs of your specific application.
The control must be cycled through a complete regeneration before the gallon override setting is stored by the
microprocessor.
NOTICE: Changing the capacity will affect the reserve capacity. An INCREASE in the gallons capacity will
DECREASE the reserve capacity. A DECREASE in the gallons capacity will INCREASE the reserve capacity.
Refer to Tables 4B and 5B to determine the units total capacity based on salt dosage and the hardness level.
The programming of the Soft-Minder
provides several settable variables, the Time-of-Day, Time-of-Regenera-
tion, Salt Dosage, Backwash Time, Brine/Rinse Time, Hardness, and Gallons to Signal. The numeric enunciator
will light for programming sequences 1-10. Refer to the programming section for further information on
programming the microprocessor.