Culligan Aqua-Cleer CC Basic Especificações

Consulte online ou descarregue Especificações para Aparelhos de ar condicionado "split system" Culligan Aqua-Cleer CC Basic. Culligan Aqua-Cleer CC Basic Specifications Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1

Culligan® Aqua-Cleer®Advanced Drinking Water Systems Owners Guide

Página 2 - CULLIGAN WATER

10component of feed water will plug a membrane over time. Use of a softener will reduce the fouling effect on a membrane. One way to detect too much h

Página 3 - Contents

Chapter Heading11To keep the Aqua-Cleer® system operating properly, it is necessary to change the filters and sanitize the system periodically. Typica

Página 4 - About Your

12Preliminary Steps:1. Check for any leaks that may exist from tubing connections or the faucet.2. Check for flow to the drain. If flowing, close tank

Página 5

Chapter Heading13Parts List Item Description1 Manifold Assembly2 SED1 FilterSED2 FilterSED3 Filter3 Carbon Block FilterGranular Activated Carbon Filte

Página 6

Chapter Heading14Important Notice: Read this Performance Data Sheet and compare the capabilities of this system with your actual water treatment need

Página 7

15Carbon Block (CB) The Carbon Block pre-filter has been tested according to NSF/ANSI 42 for the reduction of the substances listed be

Página 8

16Total Defense (TD) The Total Defense has been tested according to NSF/ANSI 42 and 53 for the reduction of the substances listed belo

Página 9 - Factors Which Affect

17Organic Chemicals Included in Surrogate Testing:Applies to Total Defense (TD) only.Substance Inuent Challenge Concentration mg/LMaximum permiss

Página 10 - Installation

Chapter HeadingInside Text18Organic Chemicals Included in Surrogate Testing (Continued):Applies to Total Defense (TD) only.Substance Inuent Challeng

Página 11

Chapter Heading19Performance Data Sheet (con’t)RO30 This system has been tested according to NSF/ANSI 58 for the reduction of the subs

Página 12 - System (con’t)

THANK YOUAND WELCOME TO YOUR NEW WORLD OF BETTER LIVING WITH CULLIGAN WATER.Notice: Do not use with water that is microbiologically unsafe or of unkno

Página 13 - Parts List

20Performance Data Sheet (con’t)RO30 with TD These systems have been tested and certified by NSF International according to NSF/ANSI 4

Página 14 - Data Sheet

21Total Defense (TD)The Total Defense has been tested according to NSF/ANSI 42 and 53 for the reduction of the substances listed below. The concentra

Página 15

22Performance Data Sheet (con’t)Organic Chemicals Included in Surrogate Testing:Applies to Total Defense (TD) only. Substance Inuent Challenge

Página 16

23Substance Inuent Challenge Concentration mg/LMaximum permissible product water concentration mg/Lsimazine 0.120 0.004styrene 0.150 0.

Página 17

24Performance Data Sheet (con’t)RO30 with AS3These systems have been tested and certified by NSF International according to NSF/ANSI 53 and 58 for th

Página 18

25AS3The AS3 has been tested according to NSF/ANSI 53 for the reduction of the substances listed below. The concentration of the indicated substances

Página 19

26AS3The AS3 has been tested according to NSF/ANSI 53 for the reduction of the substances listed below. The concentration of the indicated substances

Página 20

27Total Defense (TD)The Total Defense has been tested according to NSF/ANSI 42 and 53 for the reduction of the sub-stances listed below. The concentr

Página 21

28Organic Chemicals Included in Surrogate Testing:Applies to Total Defense (TD) only. Substance Inuent Challenge Concentration mg/LMaxi

Página 22

29Substance Inuent Challenge Concentration mg/LMaximum permissible product water concentration mg/Lsimazine 0.120 0.004styrene 0.150 0.

Página 23

Table of ContentsAbout Your System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Installation . .

Página 24

30Performance Data Sheet (con’t)RO50* This system has been tested according to NSF/ANSI 58 for the reduction of the substances listed

Página 25

31Performance Data Sheet (con’t)RO50* with TDThese systems have been tested and certified by NSF International according to NSF/ANSI 42, 53, and 58 fo

Página 26

32Performance Data Sheet (con’t)Total Defense (TD)The Total Defense has been tested according to NSF/ANSI 42 and 53 for the reduction of the substance

Página 27

33Performance Data Sheet (con’t)Organic Chemicals Included in Surrogate Testing:Applies to Total Defense (TD) only. Substance Inuent Challenge Concen

Página 28

34pentachloophenol 0.096 0.001simazine 0.120 0.004Substance Inuent Challenge Concentration mg/LMaximum permissible product water concentration mg/Ls

Página 29

35RO50* with AS3These systems have been tested and certied by NSF International according to NSF/ANSI 53 and 58 for the reduction of the substances l

Página 30

36AS3The AS3 has been tested according to NSF/ANSI 53 for the reduction of the substances listed below. The concentration of the indicated substances

Página 31

37Performance Data Sheet (con’t)RO50* with AS3, TDThese systems have been tested and certied by NSF International according to NSF/ANSI 42, 53 and 58

Página 32

38AS3The AS3 has been tested according to NSF/ANSI 53 for the reduction of the substances listed below. The concentration of the indicated substances

Página 33

39Total Defense (TD)Total Defense has been tested according to NSF/ANSI 42 and 53 for the reduction of the substances listed below. The concentration

Página 34

Chapter Heading4About Your SystemThank you for choosing a Culligan Aqua-Cleer advanced drinking water system. Your new system is designed to bring you

Página 35

40Organic Chemicals Included in Surrogate Testing:Applies to Total Defense (TD) only. Substance Inuent Challenge Concentration mg/LMaxi

Página 36

41Substance Inuent Challenge Concentration mg/LMaximum permissible product water concentration mg/Lsimazine 0.120 0.004styrene 0.150 0.

Página 37

42Performance Data Sheet (con’t)Output (Total Dissolved Solids (TDS) Reduction and Output Production)1 – RO30Tank Size 2 gallon 3 gallon 9 gallonProdu

Página 38

43AS3The AS3 has been tested according to NSF/ANSI 53 for the reduction of the substances listed below. The concentration of the indicated substances

Página 39

Chapter Heading44The Aqua-Cleer Advanced Drinking Water System with CB, GAC, or GAC-L cartridge has been tested and certified by NSF International aga

Página 40

45California CertificatesState of CaliforniaDepartment of Public HealthWater Treatment DeviceCertificate NumberDate Issued: July 16, 2010Trademark/Mod

Página 41

46California CertificatesState of CaliforniaDepartment of Public HealthWater Treatment DeviceCertificate NumberDate Issued: July 16, 2010Trademark/Mod

Página 42

47California CertificatesState of CaliforniaDepartment of Public HealthWater Treatment DeviceCertificate NumberDate Issued: July 16, 2010Trademark/Mod

Página 43

48California CertificatesState of CaliforniaDepartment of Public HealthWater Treatment DeviceCertificate NumberDate Issued: July 16, 2010Trademark/Mod

Página 44

49California CertificatesState of CaliforniaDepartment of Public HealthWater Treatment DeviceCertificate NumberDate Issued: July 16, 2010Trademark/Mod

Página 45 - Certificates

5Sequence of Filtration Type of Filtration SpecificationAdvanced FiltrationTotal DefenseArsenicPerchlorate*Speciality Carbon BlockSpecialty Media 1Spe

Página 46

50California CertificatesState of CaliforniaDepartment of Public HealthWater Treatment DeviceCertificate NumberDate Issued: July 16, 2010Trademark/Mod

Página 47

51California CertificatesState of CaliforniaDepartment of Public HealthWater Treatment DeviceCertificate NumberDate Issued: July 16, 2010Trademark/Mod

Página 48

52California CertificatesState of CaliforniaDepartment of Public HealthWater Treatment DeviceCertificate NumberDate Issued: July 16, 2010Trademark/Mod

Página 49

53California CertificatesState of CaliforniaDepartment of Public HealthWater Treatment DeviceCertificate NumberDate Issued: July 16, 2010Trademark/Mod

Página 50 - 195510

54California CertificatesState of CaliforniaDepartment of Public HealthWater Treatment DeviceCertificate NumberDate Issued: July 16, 2010Trademark/Mod

Página 51

55California CertificatesState of CaliforniaDepartment of Public HealthWater Treatment DeviceCertificate NumberDate Issued: July 16, 2010Trademark/Mod

Página 52 - 194410

56California CertificatesState of CaliforniaDepartment of Public HealthWater Treatment DeviceCertificate NumberDate Issued: July 16, 2010Trademark/Mod

Página 53

57California CertificatesState of CaliforniaDepartment of Public HealthWater Treatment DeviceCertificate NumberDate Issued: July 16, 2010Trademark/Mod

Página 54 - 196010

58California CertificatesState of CaliforniaDepartment of Public HealthWater Treatment DeviceCertificate NumberDate Issued: July 16, 2010Trademark/Mod

Página 55

59California CertificatesState of CaliforniaDepartment of Public HealthWater Treatment DeviceCertificate NumberDate Issued: July 16, 2010Trademark/Mod

Página 56 - 196110

6Total Defense:The Total Defense cartridge should be added to your system to deal with lead, mercury, aesthetic chloramines, aesthetic chlorine taste

Página 57

60Arsenic Fact SheetArsenic (abbreviated As) is found naturally in some well water. Arsenic in water has no color, taste or odor. It must be measured

Página 58 - 194910

61Arsenic Fact Sheet (con’t)Arsenic (As) is a naturally occurring contaminant found in many ground waters. It generally occurs in two forms (valences

Página 59

62Troubleshooting Guide

Página 60 - Fact Sheet

63Troubleshooting Guide (con’t)

Página 61

64Model Serial No.Date InstalledFor Service Call Culligan at:( ) -Cartridge(s) ChangedDate ServicedSediment FilterActivate

Página 62 - Troubleshooting

65Culligan Lifetime Limited WarrantyCulligan Aqua-Cleer Advanced Drinking Water SystemYou have just purchased one of the finest drinking water systems

Página 63 - Guide (con’t)

Chapter Heading7To Bottom Of RO CartridgeAqua-Cleer FaucetMonitor SensorMonitorBall ValveTankDrainDrain Line from Air Gap to Drain (3/8” Tubing)Cold W

Página 64 - Service Log

8Important considerations:• Access to the bottom (under sink) of the faucet is required for attachment of product water line.• The faucet can be ins

Página 65 - Warranty

93. Repeat steps 1-3 and install the flushed activated carbon filter cartridge into housing and the RO membrane element. Be sure the drain adapter is

Comentários a estes Manuais

Sem comentários